Insize PROMOTION

DIGITAL CALIPER

Resolution: 0.01mm/0.0005"
Model No.: 1112-150
Model No.: 1112-200
Model No.: 1112-300

View
VERNIER CALIPER

Graduation:0.02mm/0.001
Model No.: 1205-1502S
Model No.: 1205-2002S
Model No.: 1205-3002S

View
DIAL CALIPER

Graduation: 0.01mm
Model No.: 1312-150A
Model No.: 1312-200A
Model No.: 1312-300A
View

DIGITAL HEIGHT GAUGE

Resolution: 0.01mm/0.0005"
Model No.: 1150-300

View
DIAL INDICATOR

Graduation:0.01mm
Model No.: 2301-10

View
Dial Test Indicator

Graduation: 0.01mm
Model No.: 2380-08
Model No.: 2381-08

View
BORE GAUGE

Repeatability:0.003mm
Model No.: 2322-35A
Model No.: 2322-60A
Model No.: 2322-160A
Model No.: 2322-250A
View

OUTSIDE MICROMETER

Graduation:metric 0.01mm
Model No.: 3203-25A
Model No.: 3203-50A
Model No.: 3203-75A
Model No.: 3203-100A
Model No.: 3203-125A
Model No.: 3203-150A
View

HOME > fluke > additional rang > FLUKE - CODE 62

Fluke 62 Additional Rang
Why IR Thermometers?
Temperature is often the first indication of potential problems in electrical and mechanical applications. But how can you easily determine if an electrical panel has a hot spot, a motor is overheating or an HVAC system is inefficient? The answer is with an infrared (IR) thermometer. With handheld, non-contact IR thermometers, you can instantly measure equipment temperatures in hard-to-reach or hazardous areas. And with early detection of abnormal temperatures comes early correction of problems.

Fluke 62 MAX and Fluke 62 MAX+
Designed with your on-the-job needs in mind, the new Fluke 62 MAX and 62 MAX+ infrared thermometers are everything you’d expect from the experts in measurement tools. Small in size, extremely accurate and very easy to use. IP54 rated for dust and water resistance. Precise yet rugged enough to take a 3-meter drop. In fact, the 62 MAX and 62 MAX+ are so tough, they’re the only IR thermometers around you can handle without care.
SR. Fluke CODE
1 62 MAX


Specifications

Temperature Range

Fluke 62 MAX  -30 °C to 500 °C (-22 °F to 932 °F)
Fluke 62 MAX+  -30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy
Fluke 62 MAX  ±1.5 °C or ±1.5% of reading, whichever is greater
 -10 °C to 0 °C: ±2.0
 -30 °C to -10 °C: ±3.0
Fluke 62 MAX+  ±1.0 °C or ±1.0% of reading, whichever is greater
 -10 °C to 0 °C: ±2.0
 -30 °C to -10 °C: ±3.0
Response Time (95%)
Fluke 62 MAX  <500 ms (95% of reading)
Fluke 62 MAX+  <300 ms (95% of reading)
Spectral Response  8 to 14 microns
Emissivity  0.10 to 1.00

Optical Resolution

Fluke 62 MAX  10:1 (calculated at 90% energy)
Fluke 62 MAX+  12:1 (calculated at 90% energy)
Display Resolution
 0.1 °C (0.2 °F)
Repeatability of Readings
Fluke 62 MAX  ±0.8% of reading or <±1.0 °C (2 °F), whichever is greater
Fluke 62 MAX+  ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
Power
 AA battery
Battery Life
Fluke 62 MAX  10 hours with laser and backlight on
Fluke 62 MAX+  8 hours with laser and backlight on

Physical Specifications

Weight  255 g (8.99 oz)
Size  (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
Operating Temperature  0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature  -20 °C to 60 °C (-4 °F to 140 °F), (without battery)
Operating Humidity  10 % to 90 % RH non-condensing at 30 °C (86 °F)
Operating Altitude  2000 meters above mean sea level
Storage Altitude  12,000 meters above mean sea level
IP Rating  IP 54 per IEC 60529
Drop Test  3 meters
Vibration and Shock  IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC  EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval

Compliance  EN/IEC 61010-1: 2001
Laser Safety  FDA and EN 60825-1 Class II